Dimensions
|
|
70cm x 40cm x 26cm including the handle
|
|
|
|
Weight
|
|
34.2kg - Ready for operation with 2 x 3 litre tanks
19,8kg - Without tanks and soda lime
|
|
|
|
Soda lime canister
|
|
Type:
|
|
Axial
|
Soda lime:
|
|
Average 2.5kg (Sofnolime 797)
|
Running time:
|
|
180 min with dive profile (40 m)
180 min with dive profile (100 m)
|
|
|
|
Dive profile: (40 m)
|
|
40 min at 40 m, 5 min at 15 m, 9 m for the remaining time
|
|
|
|
Dive profile: (100 m)
|
|
10 min at 100 m, 1 min at 39 m, 1 min at 36 m,
2 min at 33 m, 2 min at 30 m,
2 min at 27 m, 3 min at 24 m, 4 min at 21 m,
4 min at 18 m, 6 min at 15m, 7 min at 12 m,
10 min at 9 m, 6 m for the remaining time
|
|
|
|
Test parameter:
|
|
40l/min air, 1.6l/min CO2,
4°C water temperature
|
|
|
|
Used diluent:
|
|
40 m - Air
100 m - Trimix 11/65
|
|
|
|
|
Soda lime
|
|
The only supported soda lime is: Sofnolime® 797 manufactured by Molecular Products.
|
|
|
|
Oxygen Cylinder
|
|
3 Liter steel cylinder (200 bar)
|
|
|
|
Diluent Cylinder
|
|
3 Liter steel cylinder (200 bar)
|
|
|
|
On board gas duration
|
|
Oxygen: The on board oxygen supply will last 252 minutes, if the diver consumes
1.78 liter of oxygen per minute.
3 liter x 200 bar = 600 liter - 25% reserve = 450 liter
Diluent: The duration depends on the depth and activity of the diver.
3 liter x 200 bar = 600 liter
|
|
|
|
Batteries
|
|
2 x 3.6v lithium (SAFT 14500). One battery for the controller and one battery for the HUD.
2 x 9v block lithium (Parallel operation for the solenoid)
|
|
|
|
Volume of the counter lungs
|
|
8 litres
|
|
|
|
Maximum application depth
|
|
Max. 40 m with air as diluent Max. 100 m with trimix as diluent
Warning: Dives exceeding a depth of 100 m are associated with numerous additional risks
|
|
|
|
Purity of the gases
|
|
Air:
|
|
DIN EN 12021
|
Oxygen:
|
|
>99.5% (medicinal oxygen)
|
Helium:
|
|
>99.996
|
|
|
|
|
Atmospheric pressure range
|
|
800 - 1050mbar
|
|
|
|
1st stage "oxygen"
|
|
Connection: M26x2 - medium pressure: 7.0 to 7.5 bar
|
|
|
|
1st stage "diluent"
|
|
Connection: DIN 5/8"- medium pressure: 9.0 to 10.0 bar
|
|
|
|
Oxygen control
|
|
Two oxygen setpoints (low and high). Can be switched as many times as required, also changeable under water.
|
|
|
|
Oxygen setpoint range
|
|
From 0.4 to 1.5 bar (low and high)
|
|
|
|
Oxygen warnings
|
|
|
|
|
|
Oxygen sensors
|
|
3 galvanic cells (type: R17JJ-CCR)
|
|
|
|
Operating temperatures
|
|
When diving:
|
|
+4°C to +34°C
|
Short-term (air):
|
|
-10°C to +50°C
|
Long-term (storage):
|
|
+5°C to +20°C
|
|
|
|
|